Wrist orthosis AM-OSN-U-01
OPEN WRIST BRACE
Description
Wrap around wrist support was developed according to anatomic shape, providing stabilization on wrist and radiocarpal joint.
Orthosis is made of innovative AirSanmed II™.
Wrap around design of brace allows easy-fitting and offers whole range of adjustment and stabilization for different anatomies of the wrist.
The wrist brace is additionally equipped with Soft Elastic Pad in Distal Palmar area, which makes the product more comfortable.
The fitting on the Wrist by three Velcro straps, which ends of closure are provided with Plastic Covers, specially developed for patients with limited dexterity, such as osteoarthritis and wrist instability.
The orthosis is provided with anatomically shaped, malleable and removable metal Strip for Palm (sweat resistant coating).
3 points stabilization
L3P (LOCK 3 POINTS)
Purpose of use
- after wrist injuries
- bursitis
- joint degeneration or inflammation
Sizes
Size | Wrist circumference | How to measure |
XS | 11-13 cm (4,3″-5,1″) |
|
S | 13-15 cm (5,1″-5,9″) |
|
M | 15-17 cm (6,1″-6,7″) |
|
L | 17-19 cm (6,9″-7,5″) |
|
XL | 19-21 cm (7,7″-8,3″) |
Size | Total length of the product |
XS | 23 cm (9,05″) |
S | |
M | 24 cm (9,4″) |
L | |
XL |
Left/right side available.
Colors
Gallery
Technology
MATERIALS
AirSanmed II™
AirSanmed II™ is a multi layered intelligent orthopedic textile which is perfect for orthopedic braces production. It helps to maintain its functionality and high comfort of use. External vapour barrier is washable and possible to chemical or vapour disinfection. It is perforated and laminated with off loading foam. Due to this fact, the fabric is breathable and reduces the pressure of aluminum stays and splints. Off-loading foam is connected with soft, comfort foam improving the comfort of use. It’s laminated with soft, breathable cotton with pH neutral for human’s skin. This knitted cotton is certified with OekoTex Standard100 and fully skin-friendly.
ALLOWABLE DISINFECTANTS !!! | ||
Type of active agent or surface-active agent | Maximum content in disinfectant | Spray the surface of the device with disinfectant, leave it for disinfectant’s activation, then wash the device and dry it. |
2-propane | 35% | |
1-propane | 25% | |
Ethanol | 10% | |
Alkyl Dimethyl Benzyl Ammonium Chloride | 0,2% | |
Glucoprotamine | 25% |
TECHNOLOGICAL SYSTEMS
System for Carpal Tunnel Syndrome - CTSyndrome
Carpal tunnel syndrome is the most common entrapment neuropathy encountered in clinical practice. It is caused by compression of the median nerve as it passed through the carpal canal at the wrist. The most common causes of compression of the median nerve at this location include flexor tenosynovitis, rheumatoid arthritis, pregnancy, amyloidosis and poor wrist position. Carpal tunnel syndrome presents as pain, numbness, paresthesias, and associated weakness in the hand and wrist that radiate to the thumb, index finger, middle finger and ring finger. The best treatment for carpal tunnel syndrome is using wrist splint brace. However, many patients aren’t aware that ordinary simple wrist splint worsens their carpal tunnel syndrome! Directly compression by splint exacerbates problem and pain. Furthermore, patient without entrapment neuropathy, using the wrist brace due to bones fracture, can suffer from carpal tunnel syndrome after many weeks of immobilization and wrist compression. Because of that, using the special wrist splint brace, reducing the carpal canal pressure is essential. REH4MAT introduced to mostly wrist braces innovative solution CTSyndrome. This is special pad on wrist splint which protects carpal canal against the excessive compression. Due to that fact, electrical impulses in median nerve go freely.
STIFFENINGS
Palm strip
Plastic stays
They come in various widths and thicknesses, are made of various types of plastics, such as polyamide, ABS or acrylic, and these features determine their stiffness. Thanks to their design, they are resistant to water, moisture and sweat. Products equipped with them can be washed without having to remove them from the orthosis. Our plastic stays work only in one direction, perfectly stabilize the laterally protected part of the body, adjusting to it at the same time and have a memory function, thanks to which they always return to their original shape. This function causes the stays in the orthosis to stabilize the swollen limb immediately after the injury and after the swelling has come off. The plastic stays cannot bend and that is why, they cannot correct the body posture or the secured joint.
Setting up
Downloads
ON OUR WEBSITE WE PRESENT MEDICAL DEVICES.
USE THEM ACCORDING TO THE INSTRUCTIONS FOR USE OR LABEL.
Class I medical device in accordance with Regulation (EU) 2017/745 of the European Parliament and of the Council of 5 April 2017. on medical devices.
MANUFACTURER / ADVERTISING ENTITY: REH4MAT Sp. z o.o.